Resumen

Objetivo: comparar la microfiltración de dos selladores endodónticos a base de resina, Top Seal (Densply) ® y Ad Seal (Meta Biomed)®, en dientes uniradiculares en un periodo de 24 horas, 7 y 15 dí­as, por medio de estereomicroscopio. Método: estudio experimental in vitro, se tomaron 70 dientes uniradiculares. Los conductos radiculares fueron preparados con instrumentos Protaper® Rotatorios .Grupo 1 Obturado con cono maestro Protaper ®F3 y con TopSeal (Densply)® con técnica de condensación lateral . Grupo 2 .Obturado con cono maestro único Protaper® F3 y con AdSeal (Meta Biomed)®, con técnica de condensación lateral. Se dividieron en tres subgrupos de 10 dientes cada uno para evaluarlos en tres intervalos de tiempo de 24 horas, 7 y 15 dí­as usando un método de filtración. Resultados: en condensación lateral con el cono maestro F3, en las primeras 24 horas se presentó diferencia significativa en la microfiltración del Topseal® comparada con la microfiltración del Adseal® (0.051) , a los 7 dí­as (0.214 ) y 15 dí­as (0.682 ), no se observaron diferencias significativas entre los grupos de selladores estudiados. No se observó microfiltración de un diente en el grupo de Adseal® a los 7 dí­as, y no se observó microfiltración en un diente en ambos grupos a los 15 dí­as. Conclusión: el cemento Topseal® presentó mayor microfiltración comparado con el cemento Adseal® con una diferencia significativa en el grupo de 24 horas; pero en los grupos de 7 y 15 dí­as no se encontraron diferencias significativas. Palabras clave: Selladores Endodóncicos, Penetración Bacterial, Obturación radicular, Condensación Lateral, Estereomicroscopio. abstract Objective: to compare the microleakage of two endodontic sealers resin-based, Top Seal (Densply)® and Ad Seal (Meta Biomed)® in monoradicular teeth in a period of 24 hours, 7 and 15 days, through stereomicroscope. Methods: experimental in vitro study, 70 teeth were taken. The root canals were prepared with Rotary Protaper instruments. The two groups were divided into: Group 1. Sealed master cone Protaper F3 and TopSeal®) using lateral condensation. Group 2, Sealed master cone Protaper F3 and AdSeal ®(Meta Biomed) with lateral condensation technique. The groups were divided into three subgroups of 10 teeth each to be evaluated in three time intervals of 24 hours, 1 week and 15 days.) using a filtration method. Results: the lateral condensation was performed with F3 master cone in the first 24 hours, it presents a significant difference in microleakage of the Topseal compared with the microleakage of the Adseal (0051) at the 7 days (0.214) and the 15 days (0.682) there were no significant differences between the sealers studied groups. Not observed microleakage of a one teeth in the Adseal group at the 7 days, and not observed microleakage in both groups at the 15 days. Conclusion: topseal had most microleakage compared to Adseal. Topseal cement presented a significant difference in the group of 24 hours, but in groups of 7 and 15 days, no significant differences in the amount of microleakage of two cement sealers. Key words: endodontic sealers, bacterial penetration, root filling, lateral condensation, stereomicroscope

Descargas

Los datos de descargas todavía no están disponibles.

##submission.downloads##

Publicado

2010-06-15

Cómo citar

1.
Forero L, Tinoco J, Zambrano J, Chamorro V. Comparación de la microfiltración de dos selladores endodónticos a base de resina medida por estereomicroscopio en dientes unirradiculares humanos. Estudio in vitro. Journal odont col [Internet]. 15 de junio de 2010 [citado 11 de diciembre de 2024];3(5). Disponible en: http://revistas.unicoc.edu.co/index.php/joc/article/view/91

Número

Sección

Resumenes

Artículos más leídos del mismo autor/a